[1]吴 双,朱成林,崔华伟,等.GL-CS120和JS-120型地震计性能及记录数据相干性分析[J].华南地震,2024,(04):55-65.[doi:10.13512/j.hndz.2024.04.07]
WU Shuang,ZHU Chenglin,CUI Huawei,et al.Performance and Record Data Coherence Analysis of GL-CS120 and JS-120 Seismometers[J].,2024,(04):55-65.[doi:10.13512/j.hndz.2024.04.07]
点击复制
GL-CS120和JS-120型地震计性能及记录数据相干性分析()
华南地震[ISSN:1006-6977/CN:61-1281/TN]
- 卷:
-
- 期数:
-
2024年04期
- 页码:
-
55-65
- 栏目:
-
地震科学研究
- 出版日期:
-
2024-12-30
文章信息/Info
- Title:
-
Performance and Record Data Coherence Analysis of GL-CS120 and JS-120 Seismometers
- 文章编号:
-
1001-8662(2024)04-0055-11
- 作者:
-
吴 双; 朱成林; 崔华伟; 胡旭辉; 王杰民
-
山东省地震局,济南 250014
- Author(s):
-
WU Shuang; ZHU Chenglin; CUI Huawei; HU Xuhui; WANG Jiemin
-
Shandong Earthquake Agency , Jinan 250014, China
-
- 关键词:
-
GL-CS120; JS-120; 相干性; 自噪声
- Keywords:
-
GL-CS120; JS-120; Correlation; Self-noise
- 分类号:
-
P315.6
- DOI:
-
10.13512/j.hndz.2024.04.07
- 文献标志码:
-
A
- 摘要:
-
GL-CS120和JS-120型甚宽频带地震计在国内使用较为广泛,也是“国家烈度速报与预警工程项目——山东子项目”新建基准站目前所使用的两种地震计型号,但两种型号地震计在性能和各类指标上均存在差异。通过在同一台基上安装GL-CS120和JS-120两种型号地震计,对相同频点记录的数据进行对比分析,计算其动态观测范围、地震计自噪声和不同时段记录数据的相干性。结果显示,两种型号地震计均具有良好的自噪声特性。在相同环境下,两种型号地震计在低频(1-10s)范围内记录数据的相干性较高,在长周期(10-100s)和高频(>1Hz)范围内的相干性均存在差异,受外界环境影响较大。
- Abstract:
-
GL-CS120 and JS-120 very broadband seismometers are widely used in China. They are also used in the new base station of the “National Seismic Intensity and Rapid Reporting and Early Warning Project—Shandong Sub-Project”. However, there are differences in performance and various indicators between the two types of seismometers. In this study,GL-CS120 and JS-120 seismometers were installed on the same base,and the data recorded at identical frequenciesare were compared and analyzed. The dynamic observation range, self-noise of the seismometers, and coherence of data recorded at different periods were subsequently calculated. The results indicate that both types of seismometers exhibit favorable self-noise characteristics. In the same environmental condition, the coherence of data recorded by the two types of seismometers is high in the low frequency range(1–10 s), while differences in coherence are observed in the long period(10-100 s)and high frequency range(>1 Hz),which are significantly influenced by external factors.
参考文献/References:
[1]徐果明,周蕙兰.地震学原理[M].北京:科学出版社,1982:77-133.
[2]李兴泉,邵玉平,吴朋. BBVS-60型和CMG-3ESPC型地震计性能及记录数据相干性分析[J].地震学报,2020,42(1):92-96.
[3]吴双,李小晗,王杰民,等. GL-S120与3T-120甚宽频带地震计性能对比分析[J].四川地震,2020(4):19-22.
[4]段邵鑫,乌尼尔,李晓东,等. CTS-1E、CMG-3ESPC-120型地震计工作参数对比分析[J].地震地磁观测与研究,2019, 40(4):120-124.
[5] Peterson J,Hutt C R,Holcomb L G.Test and calibration of the seismic research observatory[R]. Albuquerque,New Mexico:USGS,1980.
[6] Sleeman R. Three-channel correlation analysis:A new tech?nique to measure instrumental noise of digitizers and seismic sensors[J]. Bulletin of the Seismological Society of America, 2006,96(1):258-271.
[7] Sleman R,Peter M.A PDF representation of the STS-2 self-noise obtained from one year of data recorded in the Conrad Observatory,Austria [J]. Bulletin of the Seismological Society of America,2012,102(2):587-597.
[8]李彩华.地震计自噪声测试技术研究[D].北京:中国地震局地球物理研究所,2014.
[9]吴双,胡旭辉.基于Matlab的地震计自噪声计算可视化软件设计[J].地震地磁观测与研究,2019,41(3):232-237.
[10] Tasic I,Runovc F.Seismometer self-noise estimation using a single reference instrument[J].Journal of Seismology,2012, 16(2):183-194.
[11] Tasic I,Runovc F.Determination of a seismometer’s genera?tor constant,azimuth,and orthogonality in three-dimensional space using a reference seismometer[J].Journal of Seismolo?gy,2013,17(2):807-817.
[12]尹昕忠,陈九辉,李顺成,等.流动宽频带地震计自噪声测试研究[J].地震地质,2013,35(3):576-582.
[13]吴双,胡旭辉,李小晗,等. GL-S60、GL-CS60与3ESPC三种宽频带地震计工作性能对比[J].华北地震科学,2020, 38(S1):109-113.
[14]宋澄,张勇,邵玉平.三地震计法精确测定地震计自身噪声研究[J].华南地震,2017,37(3):98-102.
[15]李彩华,滕云田,杨大克,等.基于两道互相关模型的地震计自噪声测试分析[J].地震地磁观测与研究,2015,36 (1):100-106.
[16]崔庆谷,安晓文,邓存华,等.用相关分析法检测两种地震计性能及记录数据差异[J].地震研究,2011,34(3):313-316.