[1]路建波.嘉兴市不同年代典型砌体房屋抗震能力分析[J].华南地震,2021,41(03):92-99.[doi:10.13512/j.hndz.2021.03.13 ]
 LU Jianbo.Seismic Capacity Analysis of the Typical Masonry Building of Different Years in Jiaxing City[J].,2021,41(03):92-99.[doi:10.13512/j.hndz.2021.03.13 ]
点击复制

嘉兴市不同年代典型砌体房屋抗震能力分析()
分享到:

华南地震[ISSN:1006-6977/CN:61-1281/TN]

卷:
41
期数:
2021年03期
页码:
92-99
栏目:
地震科学研究
出版日期:
2021-09-20

文章信息/Info

Title:
Seismic Capacity Analysis of the Typical Masonry Building of Different Years in Jiaxing City
文章编号:
1001-8662(2021)03-0092-08
作者:
路建波
(浙江省地震局,杭州 310013)
Author(s):
LU Jianbo
(Zhejiang Earthquake Agency,Hangzhou 310013,China)
关键词:
抗震能力典型砌体房屋抗震能力指数震害因子
Keywords:
Seismic capacityTypical masonry building Seismic capacity indexEarthquake damage factor
分类号:
P315.9
DOI:
10.13512/j.hndz.2021.03.13
文献标志码:
A
摘要:
《中国地震动参数区划图》(GB18306-2015)实施后,嘉兴市区抗震设防烈度由六度变为七度,大量老旧房屋结构是否能够满足相应的抗震设防目标值得研究。选取了嘉兴市区 1980年代、 1990年代、 2000年代各一幢经过正规设计建造的典型砌体房屋,对三幢房屋进行了现场调查,获取结构相关参数,采用不同的方法对其抗震能力进行了分析。主要结论有:不同年代经过正规设计建造的三幢典型砌体结构,抗震能力差别显著; 80年代和 90年代砌体结构房屋,存在多方面抗震能力薄弱环节,不能满足“小震不坏,中震可修、大震不倒”的抗震设防目标; 2000年以后典型砌体房屋,构造措施完整,使用年限较短,总体分析,抗震能力较好。此研究工作为嘉兴市地震灾害风险评估、风险降低等工作提供基础依据。
Abstract:
After the implementation of“Seismic Ground Motion Parameters Zonation Map of China”(GB18306­2015), the seismic fortification intensity in Jiaxing urban area has changed from six degree to seven degree.Whether a large number of old building structures can meet the seismic fortification goals is worth studying. Thispaper selects a typical masonry building in the 1980s, 1990s, and 2000s in Jiaxing urban area that has been formally designed and constructed, conducts on-site investigations to obtain structural parameters, and uses different methods to evaluate their seismic capacity. The main conclusions are as follows:the seismic resistance of the three typical masonry buildings that have been formally designed and constructed in different years issignificantly different;the masonry buildings in the 1980s and 1990s have vulnerabilities in many aspects,which can't meet the seismic fortification goal of "small earthquakes are not bad,moderate earthquakes can be repaired,and large earthquakes can't fall; the typical masonry building in 2000 s has complete structural measures and short service life,and generally has good seismic resistance. The research work in this paper provides the basis forearthquake disaster risk assessment and risk reduction in Jiaxing City.

参考文献/References:

[1]程绍革 .消能减震与隔震技术在抗震加固工程中的应用 [J].城市与减灾, 2016(5):19-23. [2]中华人民共和国国家治理监督检验检疫总局 . GB18306­2015中国地震动参数区划图[S].北京:中国标准出版社, 2015. [3]陈国兴 .中国建筑抗震设计规范的演变与展望 [J].防灾减灾工程学报, 2003,23(1):102-113. [4]中华人民共和国国家治理监督检验检疫总局 . GB 20023­200建筑抗震鉴定标准 [S].北京:中国标准出版社, 2015. [5]高杰,冯启民,张海东 .城市群体建筑物震害模拟方法研究[J].震灾防御技术, 2007,2(2):193-200.

备注/Memo

备注/Memo:
收稿日期:2020-10-20
基金项目:浙江省重点研发计划:地震灾害风险监测与评估技术应用( 2018C03045);中国地震局地球物理研究所项目(1217203)
作者简介:路建波(1984-),男,高级工程师,主要从事地震工程方面工作。 E-mail:lujianbo1984@163.com