[1]陈贵美,谭争光,刘 锦.广东地震地下流体监测网质量与效能分析[J].华南地震,2024,(03):23-32.[doi:10.13512/j.hndz.2024.03.03]
CHEN Guimei,TAN Zhengguang,LIU Jin.Quality and Efficiency of the Guangdong Seismic Underground Fluid Monitoring Network[J].,2024,(03):23-32.[doi:10.13512/j.hndz.2024.03.03]
点击复制
广东地震地下流体监测网质量与效能分析()
华南地震[ISSN:1006-6977/CN:61-1281/TN]
- 卷:
-
- 期数:
-
2024年03期
- 页码:
-
23-32
- 栏目:
-
地震科学研究
- 出版日期:
-
2024-09-30
文章信息/Info
- Title:
-
Quality and Efficiency of the Guangdong Seismic Underground Fluid Monitoring Network
- 文章编号:
-
1001-8662(2024)03-0023-10
- 作者:
-
陈贵美; 谭争光; 刘 锦
-
广东省地震局,广州 510070
- Author(s):
-
CHEN Guimei; TAN Zhengguang; LIU Jin
-
Guangdong Earthquake Agency , Guangzhou 510070, China
-
- 关键词:
-
地下流体观测网; 观测仪器; 观测环境; 监测效能
- Keywords:
-
Underground fluid observation network; Observation instruments; Observation environment; Monitor?ing efficiency
- 分类号:
-
P315.723
- DOI:
-
10.13512/j.hndz.2024.03.03
- 文献标志码:
-
A
- 摘要:
-
依据流体学科相关评价标准,从广东地下流体观测网观测环境、观测仪器、观测质量和预测应用方面着手,结合地下流体学科台网中心提供的台站网运行监控和质量监控情况,对地下流体观测网每个观测站的观测环境、仪器的运行情况、观测仪器产出的数据的质量及其预测应用情况进行了评估。结果显示,观测站观测环境满足二类台站居多;观测数据运行率为优秀者占比:水位、水温和氡各为77.8%、63.6%和100.0%;流体仪器数据完整率全部为优秀;预测应用效能井水位和氡均为良好,水温有88.9%为良好。通过评估,较全面地分析了广东地下流体观测网存在的问题,并针对存在的不足提出改进措施及建议。
- Abstract:
-
According to the relevant evaluation standards of fluid science, the underground fluid observation network in Guangdong was studied in terms of observation environment, observation instrument, observation quality, and predicted application. Combined with the operation monitoring and quality monitoring data of the station network provided by the China Earthquake Network Center, the observation environment, instrument operation, the quality of the data produced by the monitoring instruments, and the predicted application of each observation station in the underground fluid observation network were evaluated. The results show that the majority of stations satisfy the second-class station requirements for the observation environment. The proportion of excellent observation data operation rates is as follows: water level, water temperature, and radon are 77.8%, 63.6%, and 100.0%, respectively. The data completeness of all fluid instruments is rated as excellent. The predicted application efficacy for well water level and radon are both good,with 88.9% of water temperatures being rated as good. Through the evaluation,a comprehensive analysis of the issues existing in the Guangdong underground fluid monitoring network is conducted,and improvements along with suggestions are proposed for these shortcomings.
参考文献/References:
[1]广东省地方史志编纂委员会.广东省志.地震志[M].广州:广东人民出版社,2003.
[2]广东省地震局.广东省地震监测志——中国地震监测志系列[M].北京:地震出版社,2005.
[3]中国地震局.地震及前兆数字观测技术规范——地下流体观测[M].北京:地震出版社,2001.
[4]中国地震局.地震台站建设规范地下流体台站(第1部分:水位和水温台站):DB/T 20.1-2006 [S].北京:地震出版社,2006.
[5]中国地震局监测预报司.地下流体数字观测技术[M].北京:地震出版社,2002.
[6]中国地震局监测预报司.地震地下流体理论基础与观测技术(试用本)[M].北京:地震出版社,2007.
[7]陈贵美,谭争光,刘锦,等.广东数字化形变观测资料质量评价[J].华南地震,2022,42(1):7-14.
[8]吴富春,方炜,潘存英,等.中国地震台网各类前兆手段地震监测能力的评价[J].华南地震,2007,27(2):11-17.
[9]刘春国,孔令昌,杨竹转,等.我国地震井水位观测网监测效能评估[J].中国地震,2015,31(2):329-337.
[10]陶志刚,刘春国.地下流体井水温数据质量评价指标探讨[J].地震研究,2022,45(2):340-344.
[11]车用太,王广才,鱼金子.试论“十五”期间我国地震地下流体前兆观测台网的优化与建设问题[J].国际地震动态, 2001,275(11):1-8.
[12]车用太,鱼金子.地下流体的源兆、场兆、远兆及其在地震预报中的意义[J].地震,1997,17(3):283-288.
备注/Memo
- 备注/Memo:
-
收稿日期:2023-10-22
基金项目:广东省地震局青年地震科学基金(GDDZZ202404)
作者简介:陈贵美(1969-),女,高级工程师,主要从事地震监测、数据处理及分析工作。E-mail:417540683@qq.com
更新日期/Last Update: